12.1 inch Multi-parameter Patient Monitor GT9003M

12.1 inch Multi-parameter Patient Monitor GT9003M
Product Detailed
12.1 inch multi-function patient monitor 1, ECG, RESP, NIBP, SpO2, TEMP, HR 2, CE certificate 4, 8 user interfaces

 

Features:

12.1” color TFT screenHumanized design with luminous buttonsOne-button-switch for 8 user interfacesMax 9 waveforms display simultaneouslyMax 720H trend review, 2880 sets NIBP data storageDual visual alarm lights, 3 levels sound-light alarm systemArrhythmia analysis, ST analysis, OXY-CRG analysisNurse call function; Pulse pitch modulationAnti electrosurgical unit, anti defibrillation, anti interferenceVarious extensible functions including VGA/ SYNC outputsBuilt-in chargeable lithium battery, maximum 2H useWire/ wireless to Central Monitoring SystemSuitable for common ward, operating room etc.

Standard: ECG, RESP, NIBP, SpO2(Guoteng) , TEMP, HR

Optional: Printer, Dual TEMP, EtCO , Single/Dual IBP, Nellcor/Masimo SpO AG

DisplayColor TFT 12.1inchResolution: 600×800 dpiVarious Working Interfaces Selectable:Standard Monitoring InterfaceBig Font InterfaceFull-screen Multi-lead InterfaceFull-screen multi-lead share interfaceHalf-screen Multi-lead InterfaceOXY-CRG Dynamic InterfaceTrend Concurrence InterfaceNIBP List InterfaceSweep Speed:6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s

Environment RequirementOperating: Temperature 5-40°C, Humidity≤80%Storage: Temperature -20-55°C, Humidity≤93%

Power SupplyExternal Power Supply: 100-250V AC, 50/60HzBattery Power SupplyType: Built-in Rechargeable Lithium BatteryWorking Period: ≥2 hours

ECGLead Type: 5-lead and 3-lead selectable, detected automaticallyLead Selection: Ⅰ;Ⅱ;Ⅲ;aVR;aVL;aVF;VSweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/sGain Selection:*0.25;*0.5;*1;*2;*4; AutoECG HR Range: 15-350bpmResolution and Accuracy: ±1bpm or ±1%Filter: Diagnostic ModeMonitoring ModeSugical ModeST-Segment Detection:Alarm Range: -1.2mV-1.2mVST-Segment, Arrhythmia analysis: YesARR Alarm: audible and visual alarm, alarm events recallablePacemaker Detection: Yes, and 5 types abnormal status detectable

RESPSweep Speed:6.25mm/s, 12.5mm/s, 25mm/sMethod: RA-LL impedanceOperation Mode:Auto/ManualMeasurement Range: 1-150 rPMAlarm:Yes, audible and visual alarm, alarm events recallableAccuracy: ±2 rPMApnea Alarm:5-80s

NIBPMethod:Automatic OscillometricOperation Modes: Manual/Automatic/ContinuousAuto measurement time interval: Adjustable1/2/3/4/5/10/15/30/60/90/120/240/480 minutesMeasurement Unit: mmHg/kPa selectableMeasurement Types: Systolic, Diastolic, MeanPressure Range for Adult: Systolic:25-255 mmHgDiastolic:10-220 mmHgMean:20-235 mmHgPressure Range for Pediatric: Systolic:20-180 mmHgDiastolic: 10-150 mmHgMean:10-160 mmHgPressure Range for Neonate: Systolic:20-120 mmHgDiastolic: 5-100 mmHgMean:10-110 mmHgLeak test and pressure auto calibration: YesOver-Pressure Protection: Dual Safety ProtectionResolution: 1mmHgAccuracy: Max mean error:±5mmHgMax standard deviation: ±8mmHgAlarm:Systolic, Diastolic, MeanPR from NIBP: Measurement 40-240bpmResolution: 1bpmAccuracy: 3bpm or 3%Leak test and pressure auto calibration:Yes

SpO2

Excellent measurement of low perfusionAnti interference pf movementMeasurement & Alarm Range:0-100%Resolution: 1%Accuracy: ±2%(80%-100%, Adult/Pediatric)±3%(60%-79%, Neonate)PR Measurement and Alarm Range: 25-300bpmResolution:1bpmAccuracy: 3bpmRefresh Rate:1s

TEMP

Measurement and Alarm Range: 0-50°CAccuracy: ±0.1°CChannel:Dual ChannelProbe Type: Skin, RectalAlarm: Sound, Light, Text

RecorderBuilt-in Thermal PrinterPrint Width:48mmPrint Speed:12.5mm/s, 25mm/s, 50mm/s

IBPMeasurement Pressure:ART, PA, CVP, RAP, LAP, ICP, P1, P2Measurement and Alarm Range:-30-350 mmHgResolution:1mmHgAccuracy:±2% or ±2mmHgSensitivity: 5μV/V/mmHg; Impedance range: 300-3000Ω

EtCO2

Measurement Method:Side-streamCO2 Range: 0% to 13%CO2 3 mmHg @Accuracy: ± < 5.0% CO2 (at ATPS)< 10% of reading @ > 5.0% CO2 (at ATPS)Breath Rate: 3 - 150 bpmOperating Temperature Range: 5°C to 50°CShipping / Storage Temperature Range: -40°C to 70°CAutomatic Offset Calibration: Time and temperature based,as well as on-demandInput Voltage: 5.00 Volts (± 5%)Interface: Highly configurable serial digital interface, CO2and barometric waveform data, Breath Detect Algorithm dataPneumatics:On-board aspiration pump and flow controllerConfigurable aspiration flows 50 - 250 ml/min (± 10%)Functionality available for H2O trap presence indicatorPower Consumption: 1000 mWatt (typical with pump on)Warm-up Time: 20sBaseline Recovery:5sResponse Time: Detector: 28 mSec (typical)System:100mSec (typical)